Wrong screed for the room

Gypsum Screed in a Wet Room: The Problem

Anhydrite screed is a great product in the wrong room. Wet rooms need a screed chemistry that tolerates standing water, and gypsum isn't it.

Free quote · No obligation

Get your wet room screed assessed

Name, phone, email — we'll reply the same working day with a fixed price.

Call now
Same-day reply
Fully insured
5★ reviewed

Anhydrite (gypsum/calcium-sulphate) screed is excellent for the vast majority of a house. It self-levels beautifully, wraps UFH pipework, and costs less than cement-based alternatives. But it has one hard limit that keeps coming up on site: it does not cope with sustained or repeated water exposure.

Wet rooms, by definition, put water directly onto or very close to the floor build-up on a daily basis. If an anhydrite screed ends up under a wet room without the right waterproofing detail, or without having been substituted for a cement-based screed at spec stage, it will eventually soften, lose strength or debond.

We see this most often in renovation projects where a single screed type was specified for the whole first floor and nobody flagged the en-suite as a special case. Here's what happens, how to check for it, and what the fix looks like.

Why gypsum and water don't mix

Calcium sulphate is soluble in water over time. A tanked wet room with a proper waterproof membrane above the screed protects it from direct wetting, but any breach in that membrane — a poorly sealed drain upstand, a cracked tanking corner — lets water sit against or soak into the anhydrite.

Repeated wetting and drying cycles progressively weaken the screed's surface strength, and in serious cases can cause it to turn soft or crumbly, undermining the tile bond above it.

Anhydrite vs cement-based screed for wet areas

Anhydrite (Gyvlon/Gypsol)

  • Excellent thermal performance
  • Lower cost per m²
  • Vulnerable to repeated wetting
  • Needs full tanking above it in wet rooms

Cemfloor (cement-based)

  • Stable under repeated water exposure
  • Compatible with cement tile adhesives
  • Slightly higher cost
  • Our default recommendation for wet rooms
Free quote · No obligation

Get your wet room screed assessed

If a wet room floor feels soft, sounds hollow or has visible damp, get it checked before more tiles fail. We'll survey, diagnose and quote the fix.

Call now
Same-day reply
Fully insured
5★ reviewed

How we check and remediate

  1. 1

    Establish the waterproofing detail

    We check whether a tanking membrane exists above the screed and whether it's intact — this often points to the real fault before we even touch the screed.

  2. 2

    Assess the screed condition

    Sounding, moisture testing and a scrape test tell us whether the anhydrite has actually softened or is still structurally sound under an intact membrane.

  3. 3

    Remove and re-pour if compromised

    Where the screed has degraded, the affected area is cut out and re-poured in a cement-based screed appropriate to a wet area.

  4. 4

    Correct the waterproofing

    Any tanking or drainage falls are corrected before re-tiling, so the same failure can't happen twice.