UFH diagnosis

Underfloor Heating Not Warming Up — Why & How to Fix

Cold room with UFH on is almost always one of four things — and only one of them is the boiler.

When a wet UFH system doesn't warm a room, our first four checks are always the same: cover depth over pipe, insulation below the pipe, manifold balancing, and boiler flow temperature.

Get one of them wrong and no amount of running the system will fix it.

Four common failure modes

SymptomLikely cause
Long warm-up, then room heatsScreed too deep over pipe — needs longer runtime
Room never gets warmInsufficient insulation below pipe
Some loops warm, others coldManifold not balanced or airlocked
System runs constantlyBoiler flow temp too low for radiator+UFH combo

Screed depth rules

  • 30mm minimum cover over pipe for Cemfloor
  • 35mm minimum cover for anhydrite
  • Anything less than 25mm risks pipe shadowing
  • More than 75mm makes UFH sluggish and inefficient