Screed installation methods

Floating Screed vs Bonded Screed

Almost every UFH job today uses a floating screed over insulation. Bonded screed direct to slab still has its place — mainly where insulation already sits elsewhere in the build-up.

Free quote · No obligation

Get your build-up confirmed before you order insulation

Name, phone, email — we'll reply the same working day with a fixed price.

Call now
Same-day reply
Fully insured
5★ reviewed

A floating screed sits on a compressible or semi-rigid insulation layer, entirely separated from the structural slab beneath. A bonded screed is mechanically and chemically keyed straight onto a prepared concrete sub-base with no insulation layer between them.

The two solve different problems: floating build-ups are how almost all modern UFH floors are constructed, because the insulation is what stops heat being lost downward into the ground or the floor below. Bonded screeds are used where insulation already exists elsewhere — under the slab itself, for example — and the screed's job is purely to provide the finished floor level.

Choosing between them isn't really optional once you know where your insulation sits; it's largely dictated by the rest of the build-up.

Floating vs bonded screed

FactorFloating / Bonded
Sits onInsulation layer / Prepared concrete slab
Typical minimum depth65–75mm (increases with load) / 25–30mm
UFH suitabilityStandard modern approach / Only if insulation is elsewhere in build-up
Point-load capacityLower — needs reinforcement for heavy loads / Higher, direct to structure
Common useNew-build and renovation UFH floors / Renovation floors with under-slab insulation

Practical implications of a floating build-up

  • Perimeter isolation strip is essential to allow the floating slab to move independently of walls
  • Minimum depth increases with anticipated point loads — heavy furniture or fitted kitchens need checking
  • Reinforcement (fibre or mesh) is more commonly specified in floating screeds carrying higher loads
  • UFH pipework typically clips directly onto the insulation before the pour
Free quote · No obligation

Get your build-up confirmed before you order insulation

Send us your section drawings and we'll confirm whether your project needs a floating or bonded screed before you commit to depths.

Call now
Same-day reply
Fully insured
5★ reviewed

Where confusion causes problems

The most common mistake we see on renovation projects is a floating screed specified at bonded-screed depth, because someone assumed the two were interchangeable on thickness. A floating build-up needs more depth to span the insulation and carry point loads without cracking.

If your insulation is already below the existing slab — common in some 1990s and 2000s builds — a bonded screed direct onto that slab may be all that's needed, saving significant floor build-up height.

Floating vs bonded, key numbers

50–65mm over insulation

Floating min. depth

25–40mm on prepared slab

Bonded min. depth

Higher without correct depth/reinforcement

Floating crack risk

Very low when substrate is sound

Bonded crack risk

Floating vs Bonded Screed — questions we get asked

Get your build-up confirmed before you order insulation

Send us your section drawings and we'll confirm whether your project needs a floating or bonded screed before you commit to depths.